03.11.10E — Criticality Analysis

Read the official CUI requirement and assessment content, then use the separately labeled Bare Metal Cyber perspective to connect it to implementation, evidence, and sustained operation.

2Parameters
1Source controls
1Assessment objectives
3Assessment methods

03.11 — Risk Assessment · NIST SP 800-172 Revision 3

Active
Official NIST requirement content

Security requirement

Identify critical system components and functions by performing a criticality analysis for [Organization-defined: systems, system components, or system services] at [Organization-defined: decision points].

Official NIST discussion

Discussion

Organizations conduct a functional decomposition of a system to identify mission-critical functions and system components. The functional decomposition includes the identification of organizational missions supported by the system, the specific functions to perform those missions, and traceability to the hardware, software, and firmware components that implement those functions, including when the functions are shared by components within and external to the system. The operational environment of a system or a system component may impact its criticality, including the connections to and dependencies on other systems, devices, system-of-systems, and outsourced IT services. System components that allow unmediated access to critical system components or functions are considered critical due to the inherent vulnerabilities that such components create. Criticality analysis is performed when an architecture or design is being developed, modified, or upgraded. If such analysis is performed early and throughout the system development life cycle, organizations may be able to modify the system design to reduce the critical nature of these functions and components, such as by adding redundancy or alternate paths into the system design. This requirement is sourced to a control tailored out of the SP 800-53B .13 moderate baseline in SP 800-171.

Official organization-defined parameters

Tailoring decisions required

Resolve these values through the governing organization’s approved tailoring and risk-management process before declaring the requirement implemented.

systems, system components, or system servicesorganization-defined systems, system components, or system servicessystems, system components, or system services to be analyzed for criticality are defined.
decision pointsorganization-defined decision points in the system development life cycledecision points in the system development life cycle when a criticality analysis is to be performed are defined.
Official protection strategy classifications

Protection strategies supported

These classifications are carried from the official SP 800-172 OSCAL record and help explain the enhanced requirement’s defensive purpose.

PS-PRAPenetration-Resistant Architecture
Bare Metal Cyber interpretation

Implementation perspective

Treat Criticality Analysis as an enhanced CUI protection outcome for elevated threat conditions that must be reflected in the system boundary, documented implementation, operational behavior, and assessment evidence. Pay particular attention to threat, vulnerability, likelihood, impact, criticality, and risk-response decisions for the CUI environment.

  1. Confirm the federal agency selected this enhanced requirement for the critical program or high-value asset and identify the CUI system components, services, users, and external connections in scope.
  2. Resolve every organization-defined parameter through an approved governance and tailoring process.
  3. Map each clause of the requirement to an accountable owner, implementation mechanism, and evidence source.
  4. Verify that inherited and shared implementations are supported by current provider evidence and responsibility boundaries.
  5. Collect evidence during normal operation and review changes, exceptions, and deficiencies on a risk-based cadence.

Questions to ask

  • Which critical-program or high-value-asset CUI, data flows, users, and services are protected by this enhanced requirement?
  • Which portions are implemented locally, inherited, shared, or not applicable, and what evidence supports that determination?
  • Do the system security plan, deployed configuration, operating process, and assessment evidence tell the same story?
  • What change, incident, or threshold should trigger reassessment?

Evidence and validation

  • risk assessments and threat models
  • vulnerability findings and prioritization records
  • supply-chain risk assessments
  • risk response and acceptance decisions

Common failure patterns

  • risk registers detached from technical evidence
  • vulnerability severity treated as business impact
  • assessments not updated after material change
  • accepted risks without owners or expiration
Official NIST SP 800-172A content

Assessment objectives and methods

Assessment objectives (1)
  1. critical system components and functions are identified by performing a criticality analysis for [Organization-defined: systems, system components, or system services] at [Organization-defined: decision points].

Examine

  • Risk assessment policy
  • assessment reports
  • criticality analysis and/or finalized criticality for each component and/or subcomponent
  • audit records and/or event logs
  • analysis reports
  • system security plan
  • other relevant documents or records

Interview

  • Personnel with assessment and auditing responsibilities
  • personnel with criticality analysis responsibilities
  • system/network administrators
  • personnel with information security responsibilities

Test

  • Processes for assessments and audits
  • mechanisms and/or tools supporting and/or implementing assessments and auditing
Official source-control relationships

Source NIST SP 800-53 controls

These controls are referenced by the official SP 800-172 Rev. 3 OSCAL record. Open the corresponding control pages for complete control text, enhancements, D3FEND mappings, and related learning.

Source record

Authoritative sources