03.10.07 — Physical Access Control

Read the official CUI requirement and assessment content, then use the separately labeled Bare Metal Cyber perspective to connect it to implementation, evidence, and sustained operation.

2Source controls
7Assessment objectives
3Assessment methods

03.10 — Physical Protection · NIST SP 800-171 Revision 3

Active
Official NIST requirement content

Security requirement

  1. a.Enforce physical access authorizations at entry and exit points to the facility where the system resides by:
    1. 1.Verifying individual physical access authorizations before granting access to the facility and
    2. 2.Controlling ingress and egress with physical access control systems, devices, or guards.
  2. b.Maintain physical access audit logs for entry or exit points.
  3. c.Escort visitors, and control visitor activity.
  4. d.Secure keys, combinations, and other physical access devices.
  5. e.Control physical access to output devices to prevent unauthorized individuals from obtaining access to CUI.
Official NIST discussion

Discussion

This requirement addresses physical locations containing systems or system components that process, store, or transmit CUI. Organizations determine the types of guards needed, including professional security staff or administrative staff. Physical access devices include keys, locks, combinations, biometric readers, and card readers. Physical access control systems comply with applicable laws, Executive Orders, directives, policies, regulations, standards, and guidelines. Organizations have flexibility in the types of audit logs employed. Audit logs can be procedural, automated, or some combination thereof. Physical access points can include exterior access points, interior access points to systems that require supplemental access controls, or both. Physical access control applies to employees and visitors. Individuals with permanent physical access authorizations are not considered visitors. Controlling physical access to output devices includes placing output devices in locked rooms or other secured areas with keypad or card reader access controls and only allowing access to authorized individuals, placing output devices in locations that can be monitored by personnel, installing monitor or screen filters, and using headphones. Examples of output devices include monitors, printers, scanners, facsimile machines, audio devices, and copiers.

Bare Metal Cyber interpretation

Implementation perspective

Treat Physical Access Control as a CUI protection outcome that must be reflected in the system boundary, documented implementation, operational behavior, and assessment evidence. Pay particular attention to physical access, facility protection, visitor accountability, and protection of system components that handle CUI.

  1. Confirm the requirement is in scope for the CUI system components, services, users, and external connections being assessed.
  2. Resolve every organization-defined parameter through an approved governance and tailoring process.
  3. Map each clause of the requirement to an accountable owner, implementation mechanism, and evidence source.
  4. Verify that inherited and shared implementations are supported by current provider evidence and responsibility boundaries.
  5. Collect evidence during normal operation and review changes, exceptions, and deficiencies on a risk-based cadence.

Questions to ask

  • Which CUI assets, data flows, users, and services are protected by this requirement?
  • Which portions are implemented locally, inherited, shared, or not applicable, and what evidence supports that determination?
  • Do the system security plan, deployed configuration, operating process, and assessment evidence tell the same story?
  • What change, incident, or threshold should trigger reassessment?

Evidence and validation

  • badge and visitor logs
  • physical access reviews
  • facility diagrams and sensor records
  • environmental and power test results

Common failure patterns

  • logical controls undermined by physical access
  • tailgating or visitor exceptions normalized
  • critical infrastructure omitted from access reviews
  • environmental alarms disconnected from response
Official NIST SP 800-171A content

Assessment objectives and methods

Assessment objectives (7)
  1. a.1.

    physical access authorizations are enforced at entry and exit points to the facility where the system resides by verifying individual physical access authorizations before granting access.

  2. a.2.

    physical access authorizations are enforced at entry and exit points to the facility where the system resides by controlling ingress and egress with physical access control systems, devices, or guards.

  3. b.

    physical access audit logs for entry or exit points are maintained.

  4. c.

    visitors are escorted.

  5. c.

    visitor activity is controlled.

  6. e.

    physical access to output devices is controlled to prevent unauthorized individuals from obtaining access to CUI.

  7. d.

    keys, combinations, and other physical access devices are secured.

Examine

  • physical protection policy and procedures
  • procedures for physical access control
  • physical access control logs or records
  • inventory records of physical access control devices
  • system entry and exit points
  • records of key and lock combination changes
  • storage locations for physical access control devices
  • physical access control devices
  • list of security safeguards controlling access to designated publicly accessible areas within facility
  • system security plan
  • other relevant documents or records

Interview

  • personnel with physical access control responsibilities
  • personnel with information security responsibilities

Test

  • processes for physical access control
  • mechanisms for supporting or implementing physical access control
  • physical access control devices
Official source-control relationships

Source NIST SP 800-53 controls

These controls are referenced by the official SP 800-171 Rev. 3 OSCAL record. Open the corresponding control pages for complete control text, enhancements, D3FEND mappings, and related learning.

Source record

Authoritative sources